PVC insulated steel tape armoured PVC sheathed flexible control cable
I Feature
1 shielded controlcable: 450/750v
2 No of cores : 2~37
3 Nominal cross-section: 0.75~10 mm2
4 conductor:copper
5 voltage class: 450/750V
II Structure Diagram of Control cable
III Production standard
The product is manufactured according toGB9330-88,IEC , or other standard as requried by user.
IV Application
(1)Used as power and connecting cables in mechanical engineering for tooling machinery, control unit,
production lines, transportation equipment, conveyor and assembly lines as well as in plant construction
under the circumstance that the rated voltage is up to 450/750V AC.
(2)Permissible continuous working temperature ofthe cable conductor is 70 °C
(3) Ambient temperature is not lower than 0 °C andit's minium bending 1 radius is as follows when cable is installed fornon-armored cable -not less than 6 times O>D
for armored orcopper tase shielded cable notless than 12 times
for shielded flexible cable not less than 6times O>D
Specification mm2 | O.D of Product mm | Reference weight of cable kg/km | Minimum insulation resistance at70°C (MΩ.km) | Max D.C resistance at20°C(Ω/km) |
lower limit mm | upper limit mm |
2×0.75 | 7.7 | 9.3 | 95 | 0.012 | 24.5 |
2×1.0 | 8.0 | 9.7 | 109 | 0.011 | 18.1 |
2×1.5 | 8.9 | 10.7 | 136 | 0.011 | 12.1 |
2×2.5 | 10.0 | 12.1 | 176 | 0.010 | 7.41 |
2×4 | 10.9 | 13.2 | 261 | 0.0085 | 4.61 |
2×6 | 11.9 | 14.3 | 325 | 0.0070 | 3.08 |
3×0.75 | 8.1 | 9.7 | 109 | 0.012 | 24.5 |
3×1.0 | 8.4 | 10.1 | 126 | 0.011 | 18.1 |
3×1.5 | 9.3 | 11.2 | 161 | 0.011 | 12.1 |
3×2.5 | 10.5 | 12.7 | 211 | 0.010 | 7.41 |
3×4 | 11.5 | 13.9 | 315 | 0.0085 | 4.61 |
3×6 | 13.1 | 15.8 | 400 | 0.0070 | 3.08 |
4×0.75 | 8.6 | 10.4 | 128 | 0.012 | 24.5 |
4×1.0 | 8.9 | 10.8 | 150 | 0.011 | 18.1 |
4×1.5 | 10.0 | 12.1 | 191 | 0.011 | 12.1 |
4×2.5 | 11.4 | 13.8 | 285 | 0.010 | 7.41 |
4×4 | 13.0 | 15.7 | 382 | 0.0085 | 4.61 |
4×6 | 14.4 | 17.4 | 490 | 0.0070 | 3.08 |
5×0.75 | 9.2 | 11.1 | 148 | 0.012 | 24.5 |
5×1.0 | 9.6 | 11.6 | 174 | 0.011 | 18.1 |
5×1.5 | 10.7 | 13.0 | 225 | 0.011 | 12.1 |
5×2.5 | 12.9 | 15.5 | 335 | 0.010 | 7.41 |
5×4 | 14.3 | 17.2 | 454 | 0.0085 | 4.61 |
5×6 | 15.6 | 18.8 | 587 | 0.0070 | 3.08 |
7×0.75 | 9.8 | 11.8 | 170 | 0.012 | 24.5 |
7×1.0 | 10.2 | 12.4 | 209 | 0.011 | 18.1 |
7×1.5 | 11.5 | 13.9 | 289 | 0.011 | 12.1 |
7×2.5 | 14.1 | 17.0 | 406 | 0.010 | 7.41 |
7×4 | 15.4 | 18.6 | 563 | 0.0085 | 4.61 |
7×6 | 16.8 | 20.3 | 738 | 0.0070 | 3.08 |
Note: part of technical parameters is givenfor reference.
V Production Range
Type | Name | Application | Nominalcross-section(mm2) | Number of cores |
KVV | Copper core PVC insulated PVC sheathed controlcable | For laying indoors, in cable trench, pipefixed occasions | 0.75 - 10 | 2 - 37 |
KVVP | Copper core PVC insulated PVC sheathedbraiding shielding control cable | For laying indoors, in cable trench, pipelineand other fixed shielding places | 0.75 - 10 | 2 - 37 |
KVV22 | Copper core PVC insulated steel tape armoredPVC sheathed control cable | For fixed places bearing large mechanicalforces and For laying indoors, in cable trench, pipeline | 0.75 - 10 | 2 - 37 |
KVVR | Copper core PVC insulated and PVC sheathedcontrol soft cable | For laying indoors in soft placesmobile | 0.75 - 10 | 2 - 37 |
KVVRP | Copper core PVC insulated PVC sheathedbraiding shielding control soft cable | For laying indoors mobile with soft andshielding occasion | 0.75 - 10 | 2 - |